ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 紀要
  2. スポーツと人間 : 静岡産業大学論集
  3. 7巻
  4. 2号

Reliability of interval time measurement method using video images in short distance sprint for STEAM physical education

https://shizusan.repo.nii.ac.jp/records/1993
https://shizusan.repo.nii.ac.jp/records/1993
181eb5e1-480c-43d7-8128-f59f5f745d19
名前 / ファイル ライセンス アクション
03_JO 03_JO Hirotaka, NAKANISHI Kenichiro, and KASAI Yoshiaki‗3748 (1.0 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2023-03-01
タイトル
タイトル Reliability of interval time measurement method using video images in short distance sprint for STEAM physical education
言語
言語 jpn
キーワード
主題Scheme Other
主題 Physical education class
キーワード
主題Scheme Other
主題 short distance sprint
キーワード
主題Scheme Other
主題 interval time
キーワード
主題Scheme Other
主題 video image
キーワード
主題Scheme Other
主題 measurement reliability
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 JO, Hirotaka

× JO, Hirotaka

JO, Hirotaka

Search repository
NAKANISHI, Kenichiro

× NAKANISHI, Kenichiro

NAKANISHI, Kenichiro

Search repository
KASAI, Yoshiaki

× KASAI, Yoshiaki

KASAI, Yoshiaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The demand for STEAM in school physical education is increasing. Measuring a 50 m sprint time
has been used for a long time as a teaching material to promote scientific and mathematical thinking,
but the problem is that the stopwatch has a large error margin. The standard frame rate for video
recording in schools is 30 or 60 frames per second, which is significantly less accurate than the
1,000 frames per second used in official track and field records. Based on this background, this study
examined the magnitude of error when 50 m sprint interval times were measured using video images
with standard frame rates. Four university students enrolled in a health and physical education course
participated in this study. A photoelectric sensor, 59.94 fps video image, 29.97 fps video image, and
a stopwatch were used for measurement instruments, and a person with a stopwatch and another
person operating video cameras were set 15 m and 30 m from the goal line. The measurement error
of interval times (each ten meter) was analyzed using 40 total runs, assuming the measurement by the
photoelectric sensor as the true value. As the result, the following were revealed.
 1) Errors were smaller with the stopwatch, 29.97 fps video images, and 59.94 fps video images, in
that order. However, the difference between 29.97 fps and 59.94 fps was less than 1/100th of a second.
2) The error was smaller at 30 m than at 15 m between the video camera and goal line. 3) At the 10 m
interval and further, the average error of stopwatch was 0.048 seconds, and the largest error was 0.230
seconds. On the other hand, the measurement error of the 59.94 fps video image was 0.018 seconds on
average and 0.064 seconds at the largest.
 These results suggest that by placing video cameras as far away from the finish line as possible and
using high frame rate video shooting, the measurement of interval times can be used as a teaching
material for STEAM in physical education.
書誌情報 スポーツと人間 静岡産業大学論集
en : Sports and human beings

巻 7, 号 2, p. 37-48, 発行日 2023-02-01
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 09:17:20.370024
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3