{"created":"2023-06-19T09:09:56.762245+00:00","id":1784,"links":{},"metadata":{"_buckets":{"deposit":"bf53c50d-f5bd-434c-b490-79e650f0723d"},"_deposit":{"created_by":13,"id":"1784","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"1784"},"status":"published"},"_oai":{"id":"oai:shizusan.repo.nii.ac.jp:00001784","sets":["1:227:257:258"]},"author_link":["3099","3098"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"72","bibliographicPageStart":"69","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"スポーツと人間 : 静岡産業大学論集"},{"bibliographic_title":"Sport and human beings : Journal of Shizuoka Sangyo University","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study compared the neuromuscular activation of the quadriceps femoris during eccentric and concentric cycling. Nine healthy young men performed a 30-s eccentric and concentric cycling at 350 W. Neuromuscular activation of the vastus lateralis during cycling was assessed using surface electromyography (EMG). Rating of perceived exertion (RPE) was evaluated by the Borg Scale. The EMG amplitude of the vastus lateralis was 33 ± 18% greater during concentric than eccentric cycling.\nThe RPE (16 ± 3) during concentric cycling was significantly higher than that (14 ± 4) during eccentric cycling, and the magnitude of RPE corresponded the level of “hard”. The results demonstrated that neuromuscular activation of the quadriceps femoris was lower during eccentric than concentric cycling at high intensity.","subitem_description_type":"Abstract"},{"subitem_description":"本研究は、伸張性サイクリングと短縮性サイクリング時における大腿四頭筋の神経筋活動を比較することを目的とした。健常な成人男性9 名が、350 W のパワー発揮条件において、30 秒間の伸張性サイクリングと短縮性サイクリングをそれぞれ実施した。表面筋電図を用いて、サイクリング中の外側広筋の神経筋活動を定量した。ボルグスケールを用いて、それぞれのサイクリングにおける主観的運動強度を比較した。短縮性サイクリング時の筋電図振幅は伸張性サイクリング時のものよりも33 ± 18% 大きかった( P < 0.05)。同様に、主観的運動強度は短縮性サイクリング時(16 ± 3)が伸張性サイクリング時(14 ± 4) よりも有意に高く、主観的運動強度としてきついレベルに相当した。本研究の結果、高強度で実施した伸張性サイクリング時における大腿四頭筋の神経筋活動は、短縮性サイクリングよりも低いことが示された。","subitem_description_type":"Abstract"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"江間, 諒一"},{"creatorName":"エマ, リョウイチ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"EMA , Ryoichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-02-09"}],"displaytype":"detail","filename":"本文07_6972江間諒一.pdf","filesize":[{"value":"337.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文07_6972江間諒一","url":"https://shizusan.repo.nii.ac.jp/record/1784/files/本文07_6972江間諒一.pdf"},"version_id":"e7017e11-62a2-45fa-bd51-b44c4d9c9fa8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"伸張性サイクリング時の大腿四頭筋の神経筋活動","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"伸張性サイクリング時の大腿四頭筋の神経筋活動"},{"subitem_title":"Neuromuscular activation of the quadriceps femoris during eccentric cycling","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"13","path":["258"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-02-09"},"publish_date":"2021-02-09","publish_status":"0","recid":"1784","relation_version_is_last":true,"title":["伸張性サイクリング時の大腿四頭筋の神経筋活動"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-06-19T09:20:50.505284+00:00"}